Class A + Integrated Dome Heating
Spectrally Flat & Fast Response
With integrated high-efficiency dome heating, the MS-80SH is the new standout choice for value, accuracy, speed, reliability and IEC 61724-1:2021 Class A monitoring.
The MS-80 set new industry standards on launch in 2016 and remains a class-leader for ISO 9060:2018 Class A solar sensors today, one of the few Class A pyranometers before the MS-80S and MS-80SH, in the top tier ‘fast-response’ and ‘spectrally flat’ sub-categories, with unprecedented low-zero-offset behaviour, and a 5-year recalibration interval.
The MS-80S built on that achievement with the addition of Modbus 485 RTU and SDI-12 digital outputs for improved compatibility with data loggers and SCADA systems; also introducing new internal diagnostic systems, now standard to all S-Series sensors, offering visibility over internal temperature, humidity, tilt, and roll angle; helping to ensure optimum performance without the need for regular physical checks.
These features, along with EKO’s unique 5-year recalibration interval, and new low power consumption integrated solid-state dome heater make the MS-80SH one of the best value Class A sensors available; ideal for complex networks, hard to reach locations, and monitoring networks with restricted access.
- <1.4W Integrated HighEfficiency Dome Heating for dew & frost resistance
- ISO 9060:2018 Class A, Spectrally Flat & Fast Response
- <0.5s Super-Fast response for always accurate measurements
- <1W/m² Record Lowest Zero Offset A, and <0.5% Lowest Non-Stability over 5-Years
- Level A EMI/EMC Electronics Surge Filter & Protection
- Internal Diagnostics for temperature, tilt, roll, and relative humidity
- 5 Year Warranty & Recommended Recalibration Interval
- ISO 17025 accredited
ISO 9060:2018 | Class A |
Response time 95% | < 0.5 Sec |
Zero offset A - Thermal Radiation (200W/m²) | ± 1W/m² |
Zero offset B - Temperature change (5K/hr) | ± 1W/m² |
Zero offset C - Total zero off-set | ± 2W/m² |
Non-stability (change/year) | < 0.5%/5 years |
Non-linearity (100 to 1000W/m²) | ± 0.2% |
Directional Response (at 1000W/m² | 0 to 80°) | ± 10W/m² |
Spectral Error | ± 0.2% |
Temperature Response (-20°C to 50°C) | ± 0.5% |
Tilt Response (0-90° | 1000W/m²) | ± 0.2% |
Additional Signal Processing Error | < 1 W/m² |
Wavelength Range (nm) | 285 to 3000 |
Irradiance range (W/m²) | 0 to 4000 |
Signal Output | Modbus 485 RTU / SDI-12 |
Sensor Diagnostic | Relative Humidity ± 2% Temp. ± 0.1% / Tilt Angle ± 1° |
Operating temperature | -40 to 80°C |
Supply voltage | 8 TO 30 VDC |
Power Consumption | < 1.4 W |
Ingress Protection | IP 67 |
Calibration traceability / uncertainty | ISO 17025 / WRR / < 0.7% (k = 1.96) |
Standard Cable Length | 10m (Optional lengths 20m, 30m, 50m) |