The MaxiMet range of compact weather stations is designed and manufactured by Gill Instruments. MaxiMet products use reliable, high quality instruments to provide accurate meteorological information in a wide variety of applications.
Designed and manufactured by Gill Instruments in the UK, MaxiMet® advanced compact weather stations use proven technology to measure meteorological and environmental parameters to international standards.
Cost, quality and performance requirements are met by MaxiMet® which incorporates many measurement parameters required for demanding applications including: wind, precipitation, solar radiation, temperature, humidity, pressure, low power ‘Eco Mode’, GPS, compass and many more.
Output protocol options for MaxiMet® include RS232, RS422, RS485, SDI-12, MODBUS & NMEA ensuring MaxiMet® is easy to install and easy to use.
Environmental protection to IP66 across all MaxiMet® models and MaxiMet® Marine GMX560 to IP66 and IP68.
Ultrasonic technology is used in MaxiMet® models to deliver highly accurate measurements with no moving parts to wear or recalibrate. As a result, MaxiMet® is extremely reliable and low maintenance.
Available parameters: Wind speed and direction, air temperature, relative/absolute humidity, pressure, precipitation, solar radiation, GPS coordinates / MSL (Mean Sea-Level) pressure / true wind / clock / longitude and latitude / sunrise / sunset / twilight, ground speed, compass, 2D coordinate/apparent, wind, location, height above sea level, averaging (World Meteorological Organization), gust (World Meteorological Organization), air density, barometric pressure, wet bulb, dew point, wind chill, sensor status information, heat index and more…
- Quality measurements
- Lightweight & Robust
- Low Power Mode
- Free of Charge Software
- Gill Proven Reliability
- Compact Integrated Design
- Real Time Output
- Easy Installation
- Gill Customer Support
- 2 Year Warranty
Wind Speed | |
Range | 0.01 m/s to 60 m/s |
Accuracy | ± 3% to 40 m/s, ± 5% to 60 m/s |
Resolution m/s | 0.01 |
Starting Threshold | 0.01 m/s |
Sampling Rate | 1 Hz |
Units | m/s, km/hr, mph, kts, ft/min |
Wind Direction | |
Range | 0-360° |
Accuracy | ± 3° to 40 m/s ± 5° to 60 m/s |
Resolution | 1° |
Starting Threshold | 0.05 m/s |
Sampling Rate | 1 Hz |
Units | Degrees |
Temperature | |
Range | -40°C to +70°C |
Resolution | 0.1 |
Accuracy | ± 0.3°C @ 20°C |
Sampling Rate | 1 Hz |
Units | °C, °F, °K |
Humidity | |
Range | 0-100% |
Resolution | 1% |
Accuracy | ± 2% @ 20°C (10%-90% RH) |
Sampling Rate | 1 Hz |
Units | % Rh, g/m3 |
Dew Point | |
Range | -40°C to +70°C |
Resolution | 0.1 |
Accuracy | ± 0.3°C @ 20°C |
Units | °C, °F, °K |
Sampling Rate | 1 Hz |
Pressure | |
Range | 300 to 1100 hPa |
Resolution | 0.1 hPa |
Accuracy | ± 0.5 hPa @ 25°C |
Sampling Rate | 1 Hz |
Units | hPa, mbar, mmHg, InHg |
Output | |
Output rate | 1/s, 1/min, 1/hr |
Digital Comms Modes | Serial RS232, RS422, RS485, SDI-12, NMEA, MODBUS, ASCII |
Analogue Outputs | Available via separate optional device |
Power | |
Power Supply | 5 to 30 Vdc |
Power (Nominal) 12 Vdc | 25 mA continuous high mode. 0. mA eco-power mode (1 hour polled) |
Environmental Condition | |
IP Rating | 66 |
Operational Temperature Range | -35°C to +70°C |
EMC Standard | BS EN 61326-2-1:2013 FCC, CFR Title 47, Part 15, Subpart B, Class A digital device |
CE Marking | YES |
RoHS compliant | YES |
Weight | 0.7 Kg |
Origin | UK |