The MaxiMet range of compact weather stations is designed and manufactured by Gill Instruments. MaxiMet products use reliable, high quality instruments to provide accurate meteorological information in a wide variety of applications.
Temperature, humidity, pressure. A combined instrument mounted inside three double louvered, naturally aspirated radiation shields with no moving parts. The results are high performance across each measurement over long periods of time.
Wind. Wind speed and direction measurements are provided via an ultrasonic sensor and the addition of an electronic compass provides apparent wind measurements. Average speed and direction together with WMO averages and gust data is also provided. Add GPS (optional) to provide true wind and other features.
Precipitation. An integrated optical rain gauge that automatically senses water hitting its outside surface and provides measurements based on the size and number of drops. Algorithms interpret this data and simulate the output of a tipping bucket rain gauge in a serial format. The optical rain gauge has no moving parts associated with tipping bucket gauges.
- Wind speed & Wind direction
- Temperature, humidity & pressure
- Precipitation
- Compass
- GPS (Option)
Wind Speed | |
Range | 0.01 m/s to 60 m/s |
Accuracy | ± 3% to 40 m/s, ± 5% to 60 m/s |
Resolution m/s | 0.01 |
Starting Threshold | 0.01 m/s |
Sampling Rate | 1 Hz |
Units | m/s, km/hr, mph, kts, ft/min |
Wind Direction | |
Range | 0-360° |
Accuracy | ± 3° to 40 m/s ± 5° to 60 m/s |
Resolution | 1° |
Starting Threshold | 0.05 m/s |
Sampling Rate | 1 Hz |
Units | Degrees |
Temperature | |
Range | 40°C to +70°C |
Resolution | 0.1 |
Accuracy | ± 0.3°C @ 20°C |
Sampling Rate | 1 Hz |
Units | °C, °F, °K |
Humidity | |
Range | 0-100% |
Resolution | 1% |
Accuracy | ± 2% @ 20°C (10%-90% RH) |
Sampling Rate | 1 Hz |
Units | % RH, g/m3 |
Dew Point | |
Range | -40°C to +70°C |
Resolution | 0.1 |
Accuracy | ± 0.3°C @ 20°C |
Units | 20°C Units ° |
Sampling Rate |
1 Hz |
Pressure | |
Range | 300 to 1100hpa |
Resolution | 0.1 hPa |
Accuracy | ± 0.5 hPa @ 25°C |
Sampling Rate | 1 Hz |
Units | hPa, Nbar, mmHg, inHg |
Precipitation | |
Measurement type | Optical |
Range | 0 to >300 mm/hr |
Precipitation Resolution | 0.08 mm (customer selectable) |
Repeatability | 3% |
Sampling Rate | 1 Hz |
Units | mm/hr, mm/total, in/hr, in/ total |
Heating | YES |
Outputs | |
Output rate | 1/s, 1/min, 1/hr |
Digital Comms Modes | Serial RS232, RS422, RS485, SDI-12, NMEA, MODBUS, ASCII |
Analogue Outputs | Available via separate optional device |
POWER | |
Power Supply | 5 to 30 Vdc |
Power (Nominal) 12 Vdc | 64 mA continuous high mode. 0.7 mA eco-power mode (1 hour polled) |
Environmental Condition | |
IP Rating | 66 |
Operational Temperature Range | -35°C to +70°C |
EMC Standard | BS EN 61326-2-1:2013 FCC, CFR Title 47, Part 15, Subpart B, Class A digital device |
CE Marking | YES |
RoHS compliant | YES |
Weight | 0.8 Kg |
Origin | UK |