The NR-LITE2 includes two black conical absorbers—one facing upward and the other facing downward. The absorbers are coated in PTFE, making them resistant to weather without using a fragile plastic dome. Both absorbers are calibrated to an identical sensitivity coefficient.
The NR-LITE2 has a bubble level to ensure proper installation and a rod that deters birds from roosting on the sensor. It produces a millivolt signal that is measured directly by a Campbell Scientific data logger.
Benefits and Features
- Compatible with most Campbell Scientific data loggers
- Integrated bubble level ensures proper installation
- Includes rod that deters birds from roosting on the radiometer
- PTFE-coated absorbers are weather-resistant without using a fragile plastic dome
The NR-LITE2, manufactured by Kipp & Zonen and cabled for use with Campbell Scientific data loggers, is a rugged net radiometer that measures the energy balance between incoming short-wave and long-wave infrared radiation relative to surface-reflected short-wave and outgoing long-wave infrared radiation. It is directly connected to a Campbell Scientific data logger and is widely used in agriculture and hydrology applications.
- NR-LITE2-L Net Radiometer measures the energy balance between incoming short-wave and long-wave infrared radiation relative to surface reflected short-wave and outgoing long-wave infrared radiation.
- Includes two black conical absorbers—one facing upward and the other facing downward.
- The absorbers are coated in PTFE, making them resistant to weather without using a fragile plastic dome.
- Calibrated to an identical sensitivity coefficient.
- Includes a bubble level to ensure proper installation and a rod that deters birds from roosting on the sensor.
- Produces a millivolt signal that is measured directly by a Campbell Scientific data logger.
- The only difference between the NR-Lite and the NR-Lite2 is the color of the wires.
Sensor | Two black conical absorbers—one facing upward and the other facing downward |
Measurement Description | Measures incoming and outgoing short-wave and long-wave radiation |
Spectral Range | 0.2 to 100 µm |
Response Time | < 20 s (nominal) |
Sensitivity | 10 µV W-1 m2 (nominal) |
Output Range | ±25 mV |
Measurement Range | ±2000 W m-2 |
Operating Temperature Range | -40° to +80°C |
Sensor Diameter | 8.0 cm (3.1 in.) |
Support Arm Diameter | 1.6 cm (0.6 in.) |
Support Arm Length | 80 cm (31.5 in.) |
Sensor Weight | 200 g (7.0 oz) |
Support Arm Weight | 635 g (23 oz) |